Improving Lives Through Science

Login | Register

CO₂ Incubators

CO₂ Incubators › CelCulture® CO₂ Incubators with Integrated Cooling System

CelCulture® CO₂ Incubator

CCL-__-_-P

CelCulture® CO₂ Incubators with Integrated Cooling System

The innovative Esco CelCulture® CO2 incubator provides solutions for highly specialized applications with wider temperature range. The integrated cooling system allows studies of samples that require temperature at/or below ambient temperature. 

Applications:

  • Cultivating Marine Invertebrates
  • Insect Cell Culture
  • Incubation at or Below Ambient Temperature

Features

Peltier Cooling System

  • Wider temperature ranging from 8oC below ambient to 60°C
  • Precise heating and cooling modes to secure sample safety from temperature changes

Robust Contamination Control

  • SteriSafe™ ULPA filtration ensures air chamber cleanliness
  • SwiftCon™ 90˚C validated moist heat decontamination cycle (15 hours)
  • In-line filters remove gas impurities and contaminants

Direct Heat and Air Jacket

  • Fast and uniform heating
  • Rapid temperature recovery
  • Air jacket improves chamber stability

Shelving

  • Perforated shelving to improve uniformity
  • Anti-tip
  • Stainless steel
  • Built-in grip

Rounded Corners

  • Seamless design
  • Facilitates easier cleaning

Heat Resistant CO₂ Sensor

  • IR Sensor
  • Single-beam, dual-wavelength IR sensor is drift-free
  • CARBOCAP® technology makes it stable for a long time and resistant to high heat

Isocide™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Models

Item CodeModel CodeDescription
IR SENSOR MODEL WITH INTEGRATED COOLING SYSTEM
170101 CCL-170B-8-P CelCulture® Incubator 170 L, IR Sensor, CO₂ Control, Peltier System, 230 VAC, 50/60 Hz
2170115 CCL-170B-9-P CelCulture® Incubator 170 L, IR Sensor, CO₂ Control, Peltier System, 115 VAC, 50/60 Hz
2170116 CCL-240B-8-P CelCulture® Incubator 240 L, IR Sensor, CO₂ Control, Peltier System, 230 VAC, 50/60 Hz
2170266 CCL-240B-9-P CelCulture® Incubator 240 L, IR Sensor, CO₂ Control, Peltier System, 115 VAC, 50/60 Hz
SUPPRESSED O2 MODEL WITH INTEGRATED COOLING SYSTEM
2170112 CCL-170T-8-P CelCulture® Incubator 170 L, IR Sensor, CO₂ & O₂ Control, Peltier System, 230 VAC, 50/60 Hz
2170153 CCL-170T-9-P CelCulture® Incubator 170 L, IR Sensor, CO₂ & O₂ Control, Peltier System, 115 VAC, 50/60 Hz
2170267 CCL-240T-8-P CelCulture® Incubator 240 L, IR Sensor, CO₂ & O₂ Control, Peltier System, 230 VAC, 50/60 Hz
2170268 CCL-240T-9-P CelCulture® Incubator 240 L, IR Sensor, CO₂ & O₂ Control, Peltier System, 115 VAC, 50/60 Hz

Accessories

Item CodeModel CodeDescription
5170470 COA-1001 Humidity Display, Factory-installed
5170471 COA-1001-F Humidity Display, Field-installed Kit
5170472 COA-1002 CO₂ Backup (Tank Switcher), Factory-installed
5170473 COA-1002-F CO₂ Backup (Tank Switcher), Field-installed
5170490 COA-1007 N₂ Back-up (Tank Switcher), Factory-installed
5170491 COA-1007-F N₂ Back-up (Tank Switcher), Field-installed
5170474 COA-1004 Reversed Door Swing, Factory-installed
5170475 COA-1005 Analog Outputs, Factory-installed
5170476 COA-1005-F Analog Outputs, Field-installed
5170481 COA-2005-F 2-Stage Gas Regulator for CO₂/N₂
5170483 COA-2008-F Stacking Kit (one set included with every unit purchased)
5170329 COA-2010-F Electronic CO₂ Analyzer, For CO₂ / Temp Measurement (with Temperature Probe)
5170397 COA-2016-F Electronic CO₂ + O₂ Analyzer, For CO₂ / O₂ / Temperature Measurement (with Temperature Probe)
5170398 COA-2017-F Electronic CO₂ + O₂ + RH Analyzer, For CO₂ / O₂ / RH / Temperature Measurement (with Temperature Probe)
2170021 COA-2012-F 6" Chart Recorder, Temp, 115/230 VAC, 50/60 Hz
2170022 COA-2013-F 8" Chart Recorder, Temp/Temp, 115/230 VAC, 50/60 Hz
2170023 COA-2014-F 6" Chart Recorder, Temp/RH, 115/230 VAC, 50/60 Hz
2170020 COA-2011-F IQ / OQ Documentation
5250001 COA-2015-F Voyager® Software Kit
For the complete list, please refer to our brochure

Catalogs and Brochures

Selection Criteria for CO₂ Incubators

CelCulture® CO₂ Incubator Combined Catalog

Esco CO₂ Incubator Tri-fold Brochure

References

White paper: A New Microbiological Cross Contamination Test on Esco CelCulture® CO₂ Incubator

How to Choose Your Esco CO₂ Incubators

Guide to CO₂ Incubator: Proper Installation and Maintenance

White paper: Antimicrobial Testing on Copper versus Copper Alloys

White paper: Air Cleanliness Test on CO₂ Incubator

White paper: Antimicrobial effectiveness Isocide™ versus stainless steel plate

White paper: Performance Evaluation on Esco CO₂ Incubator with Suppressed O2 in Low Ambient Temperature

White paper: Performance Evaluation of Esco Tri Gas CelCulture® CO₂ Incubator

Proper Installation and Maintenance of CO2 Incubators

CO2 Incubator Maintenance Tips and Procedure

How to Safeguard your Cell Culture Poster

Choosing the Right Sensor for CO2 Incubator

Avoiding Contamination on your CO₂ Incubator

App Note: Achieving Successful Fish Transgenesis with Esco CO2 Incubators

App Note: Cultivation of Marine Invertebrate Cells with CelCulture® CO2 Incubators

App Note: Preventing Contamination in Cell Cultures with 100 Copper Chamber CO2 Incubator

When should the CO₂ Incubator’s ULPA Filter be replaced

Everything You Need to Know Before Purchasing CO₂ Incubator