Features
Robust Contamination Control
|
|
Direct Heat and Air Jacket
|
|
Shelving
|
|
Rounded Corners
|
|
Heat Resistant CO₂ Sensor
|
|
Isocide™ Antimicrobial Powder Coating
|
Improving Lives Through Science
CO₂ Incubators
› CO₂ Incubators › CelCulture® CO₂ Incubator with Copper Interior Chamber
Esco CelCulture® presents, CO2 Incubator with pure solid copper interior, offering maximum protection for your precious samples. Copper is known to have antimicrobial properties. It can inhibit the growth of common culture microbial contaminants such as E. coli, S. aureus, etc.
Applications:
Robust Contamination Control
|
|
Direct Heat and Air Jacket
|
|
Shelving
|
|
Rounded Corners
|
|
Heat Resistant CO₂ Sensor
|
|
Isocide™ Antimicrobial Powder Coating
|
Item Code | Model Code | Description |
---|---|---|
IR SENSOR MODEL WITH 100% COPPER CHAMBER | ||
2170081 | CCL-050B-8-Cu | CelCulture® Incubator 50 L, IR Sensor, CO₂ Control, 230 VAC, 50/60 Hz (Without Decon Pump) |
2170083 | CCL-170B-8-Cu | CelCulture® Incubator 170 L, IR Sensor, CO₂ Control, ULPA, 230 VAC, 50/60 Hz |
2170085 | CCL-240B-8-Cu | CelCulture® Incubator 240 L, IR Sensor, CO₂ Control, ULPA, 230 VAC, 50/60 Hz |
2170082 | CCL-050B-9-Cu | CelCulture® Incubator 50 L, IR Sensor, CO₂ Control, 115 VAC, 50/60 Hz (Without Decon Pump) |
2170084 | CCL-170B-9-Cu | CelCulture® Incubator 170 L, IR Sensor, CO₂ Control, ULPA, 115 VAC, 50/60 Hz |
2170086 | CCL-240B-9-Cu | CelCulture® Incubator 240 L, IR Sensor, CO₂ Control, ULPA, 115 VAC, 50/60 Hz |
2170351 | CCL-170B-8-Cu-NF | CelCulture® Incubator 170L IR Sensor, CO₂ Control , Moist Heat Decon 230VAC 50/60HZ, (No ULPA Filter) |
2170353 | CCL-240B-8-Cu-NF | CelCulture® Incubator 240L IR Sensor, CO₂ Control , Moist Heat Decon 230VAC 50/60HZ, (No ULPA Filter) |
2170355 | CCL-170B-9-Cu-NF | CelCulture® Incubator 170L IR Sensor, CO₂ Control , Moist Heat Decon,115 VAC, 50/60 Hz (No ULPA Filter) |
2170357 | CCL-240B-9-Cu-NF | CelCulture® Incubator 240L IR Sensor, CO₂ Control , Moist Heat Decon,115 VAC, 50/60 Hz (No ULPA Filter) |
SUPPRESSED O2 MODEL WITH COPPER CHAMBER | ||
2170087 | CCL-050T-8-Cu | CelCulture® Incubator 50 L, IR Sensor, CO₂ & O₂ Control, 230 VAC, 50/60 Hz (Without Decon Pump) |
2170089 | CCL-170T-8-Cu | CelCulture® Incubator 170 L, IR Sensor, CO₂ & O₂ Control, ULPA, 230 VAC, 50/60 Hz |
2170111 | CCL-240T-8-Cu | CelCulture® Incubator 240 L, IR Sensor, CO₂ & O₂ Control, ULPA, 230 VAC, 50/60 Hz |
2170088 | CCL-050T-9-Cu | CelCulture® Incubator 50 L, IR Sensor, CO₂ & O₂ Control, 115 VAC, 50/60 Hz (Without Decon Pump |
2170090 | CCL-170T-9-Cu | CelCulture® Incubator 170 L, IR Sensor, CO₂ & O₂ Control, ULPA, 115 VAC, 50/60 Hz |
2170092 | CCL-240T-9-Cu | CelCulture® Incubator 240 L, IR Sensor, CO₂ & O₂ Control, ULPA, 115 VAC, 50/60 Hz |
2170352 | CCL-170T-8-Cu-NF | CelCulture® Incubator 170L IR Sensor, CO₂ & O₂ Control, Moist Heat Decon 230VAC 50/60HZ, (No ULPA Filter) |
2170354 | CCL-240T-8-Cu-NF | CelCulture® Incubator 240L IR Sensor, CO₂ & O₂ Control, Moist Heat Decon 230VAC 50/60HZ, (No ULPA Filter) |
2170356 | CCL-170T-9-Cu-NF | CelCulture® Incubator 170L IR Sensor, CO₂ & O₂ Control, Moist Heat Decon,115 VAC, 50/60 Hz(No ULPA Filter) |
2170358 | CCL-240T-9-Cu-NF | CelCulture® Incubator 240L IR Sensor, CO₂ & O₂ Control, Moist Heat Decon,115 VAC, 50/60 Hz(No ULPA Filter) |
Item Code | Model Code | Description |
---|---|---|
5170470 | COA-1001 | Humidity Display, Factory-installed |
5170471 | COA-1001-F | Humidity Display, Field-installed Kit |
5170472 | COA-1002 | CO₂ Backup (Tank Switcher), Factory-installed |
5170473 | COA-1002-F | CO₂ Backup (Tank Switcher), Field-installed |
5170490 | COA-1007 | N₂ Back-up (Tank Switcher), Factory-installed |
5170491 | COA-1007-F | N₂ Back-up (Tank Switcher), Field-installed |
5170474 | COA-1004 | Reversed Door Swing, Factory-installed |
5170475 | COA-1005 | Analog Outputs, Factory-installed |
5170476 | COA-1005-F | Analog Outputs, Field-installed |
5170481 | COA-2005-F | 2-Stage Gas Regulator for CO₂/N₂ |
5170483 | COA-2008-F | Stacking Kit (one set included with every unit purchased) |
5170329 | COA-2010-F | Electronic CO₂ Analyzer, For CO₂ / Temp Measurement (with Temperature Probe) |
5170397 | COA-2016-F | Electronic CO₂ + O₂ Analyzer, For CO₂ / O₂ / Temperature Measurement (with Temperature Probe) |
5170398 | COA-2017-F | Electronic CO₂ + O₂ + RH Analyzer, For CO₂ / O₂ / RH / Temperature Measurement (with Temperature Probe) |
2170021 | COA-2012-F | 6" Chart Recorder, Temp, 115/230 VAC, 50/60 Hz |
2170022 | COA-2013-F | 8" Chart Recorder, Temp/Temp, 115/230 VAC, 50/60 Hz |
2170023 | COA-2014-F | 6" Chart Recorder, Temp/RH, 115/230 VAC, 50/60 Hz |
2170020 | COA-2011-F | IQ / OQ Documentation |
5250001 | COA-2015-F | Voyager® Software Kit |
For the complete list, please refer to our brochure |
Selection Criteria for CO₂ Incubators
CelCulture® CO₂ Incubator Combined Catalog
Esco CO₂ Incubator Tri-fold Brochure
White paper: A New Microbiological Cross Contamination Test on Esco CelCulture® CO₂ Incubator
How to Choose Your Esco CO₂ Incubators
Guide to CO₂ Incubator: Proper Installation and Maintenance
White paper: Antimicrobial Testing on Copper versus Copper Alloys
White paper: Air Cleanliness Test on CO₂ Incubator
White paper: Antimicrobial effectiveness Isocide™ versus stainless steel plate
White paper: Performance Evaluation on Esco CO₂ Incubator with Suppressed O2 in Low Ambient Temperature
White paper: Performance Evaluation of Esco Tri Gas CelCulture® CO₂ Incubator
Proper Installation and Maintenance of CO2 Incubators
CO2 Incubator Maintenance Tips and Procedure
How to Safeguard your Cell Culture Poster
Choosing the Right Sensor for CO2 Incubator
Avoiding Contamination on your CO₂ Incubator
App Note: Achieving Successful Fish Transgenesis with Esco CO2 Incubators
App Note: Cultivation of Marine Invertebrate Cells with CelCulture® CO2 Incubators
App Note: Preventing Contamination in Cell Cultures with 100 Copper Chamber CO2 Incubator
When should the CO₂ Incubator’s ULPA Filter be replaced
Everything You Need to Know Before Purchasing CO₂ Incubator